Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int Breastfeed J ; 19(1): 27, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38641819

RESUMEN

BACKGROUND: Lactational mastitis is a common painful and debilitating inflammation of breast tissue, generally treated conservatively or with pus puncture in case of breast abscess. However, treating mastitis in patients with implantable surgical material located in the affected breast region can be extremely challenging. We present an unusual case of lactational mastitis complicated by pacemaker pocket infection in a breastfeeding mother. CASE PRESENTATION: A 35-year-old pacemaker-dependent female developed lactational mastitis seven weeks postpartum. Initially, the condition was treated conservatively with analgesics and antibiotics. After abscess formation, pus was aspirated using fine-needle aspiration technique. Four weeks after mastitis resolution, pacemaker pocket infection developed. According to current cardiovascular implantable electronic device infection treatment guidelines a complete surgical extraction of the entire electronic system, followed by targeted antibiotic treatment and reimplantation of a new device after infection resolution, was recommended. However, after thorough discussion with the young woman and her family and after detailed review of surgery-related risks, she declined a potentially high-risk surgical procedure. Thus, only the pulse generator was explanted; pacing leads positioned in the sub-pectoral pocket; new pacemaker implanted on the contralateral side and broad-spectrum antibiotic therapy continued for six weeks. After breastfeeding cessation, and with chronic fistula development at the primary pacemaker implantation site, the possibility of delayed surgical intervention including complete extraction of retained pacemaker leads was again thoroughly discussed with her. After thoughtful consideration the woman consented to the proposed treatment strategy. A surgical procedure including transvenous lead extraction through the primary implantation venous entry site, using hand-powered bidirectional rotational sheaths, was successfully performed, removing all retained leads through the left subclavian venous entry site, and leaving the fully functional and clinically uninfected pacemaker on the contralateral site intact. CONCLUSION: Although patients' decisions for delayed extraction in a case of cardiovascular implantable electronic device infection should be discouraged by attending physicians and members of interdisciplinary teams, our case shows that a stepwise treatment strategy may be successful as a bailout clinical scenario in patients with specific requests, demands and / or clinical needs.


Asunto(s)
Mastitis , Marcapaso Artificial , Humanos , Femenino , Adulto , Lactancia Materna , Absceso/tratamiento farmacológico , Mastitis/terapia , Marcapaso Artificial/efectos adversos , Lactancia , Antibacterianos/uso terapéutico
2.
J Cardiothorac Surg ; 7: 75, 2012 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-22898299

RESUMEN

Ischemic rupture of the anterolateral papillary muscle is uncommon due to its dual blood supply. It usually follows an ischemic event involving branches of the left circumflex or left anterior descending arteries. We present a case of a patient admitted with an acute inferior wall myocardial infarction and an isolated distal right coronary artery occlusion. Acute mitral regurgitation with rupture of the anterolateral papillary muscle was diagnosed on the fifth post-infarction day. The patient underwent mitral valve replacement and coronary artery bypass grafting to the posterior descending artery. We conclude that anterolateral papillary muscle rupture may also result from an isolated right coronary lesion.


Asunto(s)
Rotura Cardíaca Posinfarto/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/cirugía , Puente de Arteria Coronaria , Electrocardiografía , Resultado Fatal , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...